Alltech
Gas Purifiers
Moisture
Trap Specifications
| Photo |
Description |
Compounds
Removed |
(ML) |
Efficiency |
Replacement |
Limit
(PSIG) |
| A |
Baseplate
Moisture Trap (120)cc |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
12 |
<1ppm |
Refill |
100 |
| A |
Baseplate
Moisture Trap (400)cc |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
33 |
<1ppm |
Refill |
100 |
| B |
Moisture
Trap Cartridge |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
14 |
<1ppm |
Refill |
100 |
| C |
In-Line
Moisture Trap (120cc) |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
12 |
<1ppm |
Refill |
100 |
| C |
In-Line
Moisture Trap (400cc) |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
33 |
<1ppm |
Refill |
100 |
| D |
Glass
Moisture Trap |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
16 |
<1ppm |
Refill |
100 |
| E |
High
Pressure Gas Drier |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
27 |
<1ppm |
Disposable |
1800 |
| F |
Big
Moisture Trap |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
130 |
<1ppm |
Refill |
250 |
| G |
All-Pure™
Moisture Trap |
H2O |
- |
<1ppb |
Regenerate |
250 |
| H |
Traditional
Hydro-Purge® |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
13 |
<1ppm |
Refill |
100 |
| I |
Hydro-Purge
II® (120cc) |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
19 |
<1ppm |
Refill |
100 |
| I |
Hydro-Purge
II® (200cc) |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
27 |
<1ppm |
Refill |
100 |
| J |
SS
Hydro-Purge® |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
9 |
<1ppm |
Refill |
400 |
| K |
Economy
Moisture Trap |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
31 |
<1ppm |
Disposable |
100 |
| L |
Sodium
Sulphate Trap |
H2O |
- |
- |
Refill |
100 |
Remove
Moisture From Your Gas Stream
*Prevent Stationary Phase Degradation
Moisture
contamination of gas cylinders, regulators, and gas lines can
inadvertently occur when room air enters the gas system while
changing cylinders. Moisture can have a detrimental effect on
the quality of your chromatography. It degrades the stationary
phase and decreases the life of your analytical column. An Alltech
Moisture Trap will remove moisture from your gas stream to eliminate
these problems. Both indicating and non-indicating purifiers are
available. The adsorbent bed of the indicating trap shows a colour
change when it becomes saturated. They are manufactured with metal
bodies and are suitable for high pressure and bulk purification
applications.
Moisture
Trap material
Most
moisture traps are filled with molecular sieve (zeolites).The
crystalline structure of the molecular sieve consists of SiO4 and Al304 groups, the cations to balance the negative charge
of the Aluminosilicate structure, and the water of hydration.
When the crystalline structures lose the water of hydration, they
have the ability to adsorb molecules with critical dimensions
less than their effective pore size. Molecular sieves have a strong
affinity for water and are extremely effective in drying gases
and liquids in both static and dynamic applications.
|

A-
Baseplate Format |

B-
Cartridge Format
|
Moisture
Trap Refill Kits
| Description |
Trap
Part No |
Part
No |
| For
Moisture Cartridge |
81005 |
8132 |
| For
Moisture Traps |
8121,
8125, 8123, 8128, 8122, 8126, 8127, 8130 |
8132 |
| For
Glass Moisture Traps |
7214,
7216 |
7218 |
| For
High Pressure Gas Drier |
8113 |
- |
| For
BIG Moisture Traps |
7207,
7209, 7211 |
7202 |
| For
Hydro-Purges® |
14505,
14503, 14626, 14625, 14628, 14627 |
14637 |
| For
Economy Gas Purifiers |
8151,
8153, 8155, 8157 |
- |
| For
Sodium Sulfate Trap |
81533 |
81534 |
Alltech
Moisture Traps
| Format
Type |
Photo |
Description |
Indicator |
Size |
Dimensions |
Fitting |
Part
No. |
| Baseplate
Format
|
A |
Baseplate
Moisture Trap |
Yes |
120cc |
14.5"
x 1.5" |
1/8" |
8122 |
| A |
|
Yes |
120cc |
14.5"
x 1.5" |
1/4" |
8126 |
| A |
|
Yes |
400cc |
17"
x 2" |
1/8" |
8127 |
| A |
|
Yes |
400cc |
17"
x 2" |
1/4" |
8130 |
| Cartridge
Format*
|
B |
Cartridge
Moisture Trap |
Yes |
- |
13"
x 1.5" |
- |
81005 |
| In-Line
Format
|
C |
In-Line
Moisture Trap |
Yes |
120cc |
14.5"
x 1.5" |
1/8" |
8121 |
| C |
|
Yes |
120cc |
14.5"
x 1.5" |
1/4" |
8125 |
| C |
|
Yes |
400cc |
17"
x 2" |
1/8" |
8123 |
| C |
|
Yes |
400cc |
17"
x 2" |
1/4" |
8128 |
| D |
Glass
Moisture Trap |
Yes |
100cc |
13"
x 1.5" |
1/8" |
7214 |
| D |
|
Yes |
100cc |
13"
x 1.5" |
1/4" |
7216 |
| E |
Hight
Pressure Gas Drier |
No |
200cc |
10"
x 1.5" |
1/4" |
8113 |
| F |
BIG
Moisture Trap |
No |
750cc |
17"
x 2.4" |
1/8" |
7207 |
| F |
|
No |
750cc |
17"
x 2.4" |
1/4" |
7209 |
| F |
|
No |
750cc |
17"
x 2.4" |
1/2" |
7211 |
| G |
ALL-Pure™
Moisture Trap |
No |
- |
21"
x 1.5" |
1/8" |
7034 |
| G |
|
No |
- |
21"
x 1.5" |
1/4" |
7036 |
| H |
Traditional
Hydro-Purge® |
Yes |
120cc |
10.5"
x 1.5" |
1/8" |
14505 |
| H |
|
Yes |
120cc |
10.5"
x 1.5" |
1/4" |
14503 |
| I |
Hydro-Purge
II® |
Yes |
120cc |
9"
x 1.5" |
1/8" |
14626 |
| I |
|
Yes |
120cc |
9"
x 1.5" |
1/4" |
14625 |
| I |
|
Yes |
200cc |
12"
x 1.5" |
1/8" |
14628 |
| I |
|
Yes |
200cc |
12"
x 1.5" |
1/4" |
14627 |
| J |
SS
Hydro-Purge® |
No |
- |
13"
x 1.2" |
1/8" |
14517 |
| J |
|
No |
- |
13"
x 1.2" |
1/4" |
14515 |
| K |
Economy
Gas Purifiers |
Yes |
200cc |
6"
x 2" |
1/8"
Brass |
8151 |
| K |
|
Yes |
200cc |
6"
x 2" |
1/4"
Brass |
8153 |
| K |
|
Yes |
200cc |
6"
x 2" |
1/8"
SS |
8155 |
| K |
|
Yes |
200cc |
6"
x 2" |
1/4"
SS |
8157 |
| L |
Sodium
Sulfate Trap |
Yes |
200cc |
6"
x 2" |
1/4" |
81533 |
*
Requires cartridge Baseplate unit.
|