Alltech Gas Purifiers- Oxygen Traps
Oxygen Trap Specifications
Photo |
Description |
Compunds Removed |
Capacity (ML) |
Efficiency |
Replacement |
Pressure Limit (PSIG) |
A |
AT™-Indicating Oxy Cartridge |
02, H20 |
104 |
<1ppb |
Disposable |
100 |
B |
AT™-Omni Cartridge |
02, H20, Organics |
48 |
<1ppb |
Disposable |
100 |
C |
High Pressure Oxy-Trap™ |
02, |
452 |
<1ppb |
Regenerate |
1800 |
D |
Big Oxy Trap™ |
02, |
3000 |
<50ppb |
Regenerate |
250 |
E |
All-Pure™ Oxygen Trap |
02, H20 |
1030 |
<5ppb |
Regenerate |
25 |
F |
Oxy-Trap™ |
02, |
133 |
<1ppb |
Regenerate |
100 |
G |
Large Oxy-Trap™ |
02, |
206 |
<1ppb |
Regenerate |
100 |
H |
Indicating Oxy-Trap™ |
02, |
20 |
<1ppb |
Regenerate |
100 |
I |
AT™-Super Indicating Oxy-Trap™ |
02, |
22 |
<1ppb |
Regenerate |
100 |
J |
Oxy-Purge® N |
02, H20 |
156 |
<30ppb |
Regenerate |
250 |
K |
Indicating Oxy-Purge® |
02, |
4 |
<3ppb |
Regenerate |
100 |
L |
Low Pressure Oxisorb® |
02, H20 |
48 |
<50ppb |
Replace |
90 |
M |
High Pressure Oxisorb® |
02, H20 |
48 |
<50ppb |
Replace |
3000 |
N |
Oxiclear® |
02, H20, Organics |
48 |
<5ppb |
Disposable |
125 |
Remove Oxygen to Less than 1ppb
*Protect Analytical Columns from Oxygen Contamination
Oxygen is the most critical of all impurities found in gas streams. Capillary columns and polar packed columns are unable to tolerate even small amounts of oxygen. Oxygen oxidizes the stationary phase deteriorating column performance and reducing column life. The oxidation products are volatile and cause baseline noise and drift when they reach the detector. This problem worsens as the column temperature increases. Oxygen also adversely affects analyses performed at high sensitivities or by component specific detectors. It can cause filament damage and burnout in GC/MS.
Indicators Take the "Guesswork" out of Trap Maintenance
An indicating oxygen trap provides an easy and convenient means for monitoring the performance of your large capacity non-indicating oxygen trap. Simply install the indicating oxygen trap in series after the large capacity trap. The indicating oxygen trap shows oxygen removal by changing colour as the adsorbent material depletes. When the indicating trap starts to show a colour change, the large trap is almost spent and it is time to replace it.
A |
B |
Oxygen Trap Refill Kits and Regeneration Service
Regeneration Service
Description |
Trap Part Number |
Part Number |
For AT-Indicating Oxy Cartridge |
81015 |
N/A* |
For AT-Omni Cartridge |
81012 |
N/A* |
For High Pressure Oxy-Trap™ |
8,115 |
8147 |
For BIG Oxygen Trap™ |
7213,7215,7217 |
7204 |
For ALL-Pure™ Oxygen Trap |
7040, 7042 |
7050 |
For Oxy-Trap™ with 1/8" fittings |
4001 |
4001R |
For Oxy-Trap™ with 1/4" fittings |
4002 |
4002R |
For Large Oxy-Trap™ |
4003 |
4003R |
For Indicating Oxy-Trap™ |
4004 |
4014 |
For AT-Super Indicating Oxy-Trap™ |
4334 |
43341 |
For Indicating Oxy-Purge® |
14562,14563 |
N/A* |
For Oxy Clear® |
8864, 8866 |
N/A* |
*Not applicable-traps cannot be regenerated
Refill Cartridge
Description |
Trap Part Number |
Part Number |
Active Cartridge for Oxisorb |
60678, 60679 |
60680 |
Alltech Oxygen Traps
Format Type |
Photo |
Description |
Indicator |
Dimensions |
Fitting |
Part No |
Cartridge Format* |
A |
AT-Indicating Oxy Cartridge |
Yes |
13" x 1.5" |
- |
81015 |
B |
AT-Omni Cartridge |
Yes |
13" x 1.5" |
- |
81012 |
|
In-Line Format |
C |
High Pressure Oxy-Trap |
No |
10.5" x 1.5" |
1/4" |
8115 |
D |
BIG Oxygen Trap |
No |
17" x 2.4" |
1/8" |
7213 |
|
D |
No |
17" x 2.4" |
1/4" |
7215 |
||
D |
No |
17" x 2.4" |
1/2" |
7217 |
||
E |
ALL-Pure Oxygen Trap |
No |
21" x 1.5" |
1/8" |
7040 |
|
E |
No |
21" x 1.5" |
1/4" |
7042 |
||
F |
Oxy-Trap |
No |
3.5"dia. Coil |
1/8" |
4001 |
|
F |
No |
3.5"dia. Coil |
1/4" |
4002 |
||
G |
Large Oxy-Trap |
No |
3-7/8"dia.Coil |
1/4" |
4003 |
|
G |
No |
3.9"dia.Coil |
1/4" |
81025 |
||
H |
Indicating Oxy-Trap |
Yes |
18" x 3/8" |
1/4"** |
4004 |
|
I |
AT-Super Indicating Oxy Trap |
Yes |
18" x 3/8" |
1/4"** |
4334 |
|
J |
Oxy-Purge N |
No |
10.5" x 1.5" |
1/8" |
14636 |
|
J |
No |
10.5" x 1.5" |
1/4" |
14635 |
||
K |
Indicating Oxy-Purge |
Yes |
10" x 1.5" |
1/8" |
14563 |
|
K |
Yes |
10" x 1.5" |
1/4" |
14562 |
||
L |
Low Pressure Oxisorb |
No |
9" x 1" |
1/4" |
60678 |
|
M |
High Pressure Oxisorb |
No |
9" x 1" |
1/4" |
60679 |
|
N |
Oxiclear Disposable |
No |
5.5" x 2" |
1/8" |
8866 |
|
N |
No |
5.5" x 2" |
1/4" |
8864 |
C |
H |
D |
J |
E |
K |
F |
L |
G |
N |
* Requires cartridge holder unit.
**Reducing Ferrules are Supplied for installation into 1/8" gas lines.