Alltech Gas Purifiers
Moisture Trap Specifications
Photo
|
Description
|
Compounds Removed |
(ML)
|
Efficiency
|
Replacement
|
Limit (PSIG) |
A |
Baseplate Moisture Trap (120)cc |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
12 |
<1ppm |
Refill |
100 |
A |
Baseplate Moisture Trap (400)cc |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
33 |
<1ppm |
Refill |
100 |
B |
Moisture Trap Cartridge |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
14 |
<1ppm |
Refill |
100 |
C |
In-Line Moisture Trap (120cc) |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
12 |
<1ppm |
Refill |
100 |
C |
In-Line Moisture Trap (400cc) |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
33 |
<1ppm |
Refill |
100 |
D |
Glass Moisture Trap |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
16 |
<1ppm |
Refill |
100 |
E |
High Pressure Gas Drier |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
27 |
<1ppm |
Disposable |
1800 |
F |
Big Moisture Trap |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
130 |
<1ppm |
Refill |
250 |
G |
All-Pure™ Moisture Trap |
H2O |
- |
<1ppb |
Regenerate |
250 |
H |
Traditional Hydro-Purge® |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
13 |
<1ppm |
Refill |
100 |
I |
Hydro-Purge II® (120cc) |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
19 |
<1ppm |
Refill |
100 |
I |
Hydro-Purge II® (200cc) |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
27 |
<1ppm |
Refill |
100 |
J |
SS Hydro-Purge® |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
9 |
<1ppm |
Refill |
400 |
K |
Economy Moisture Trap |
H2O, HCI, SO2, NO2, H2S, CO2, Oil, Small Aliphatics |
31 |
<1ppm |
Disposable |
100 |
L |
Sodium Sulphate Trap |
H2O |
- |
- |
Refill |
100 |
Remove Moisture From Your Gas Stream
*Prevent Stationary Phase Degradation
Moisture contamination of gas cylinders, regulators, and gas lines can inadvertently occur when room air enters the gas system while changing cylinders. Moisture can have a detrimental effect on the quality of your chromatography. It degrades the stationary phase and decreases the life of your analytical column. An Alltech Moisture Trap will remove moisture from your gas stream to eliminate these problems. Both indicating and non-indicating purifiers are available. The adsorbent bed of the indicating trap shows a colour change when it becomes saturated. They are manufactured with metal bodies and are suitable for high pressure and bulk purification applications.
Moisture Trap material
Most moisture traps are filled with molecular sieve (zeolites).The crystalline structure of the molecular sieve consists of SiO4 and Al304 groups, the cations to balance the negative charge of the Aluminosilicate structure, and the water of hydration. When the crystalline structures lose the water of hydration, they have the ability to adsorb molecules with critical dimensions less than their effective pore size. Molecular sieves have a strong affinity for water and are extremely effective in drying gases and liquids in both static and dynamic applications.
A- Baseplate Format |
B- Cartridge Format
|
Moisture Trap Refill Kits
Description |
Trap Part No |
Part No |
For Moisture Cartridge |
81005 |
8132 |
For Moisture Traps |
8121, 8125, 8123, 8128, 8122, 8126, 8127, 8130 |
8132 |
For Glass Moisture Traps |
7214, 7216 |
7218 |
For High Pressure Gas Drier |
8113 |
- |
For BIG Moisture Traps |
7207, 7209, 7211 |
7202 |
For Hydro-Purges® |
14505, 14503, 14626, 14625, 14628, 14627 |
14637 |
For Economy Gas Purifiers |
8151, 8153, 8155, 8157 |
- |
For Sodium Sulfate Trap |
81533 |
81534 |
Alltech Moisture Traps
|
![]() H |
|
![]() I |
|
![]() J |
|
![]() K |
|
![]() L |
Format Type |
Photo |
Description |
Indicator |
Size |
Dimensions |
Fitting |
Part No. |
Baseplate Format |
A |
Baseplate Moisture Trap |
Yes |
120cc |
14.5" x 1.5" |
1/8" |
8122 |
A |
Yes |
120cc |
14.5" x 1.5" |
1/4" |
8126 |
||
A |
Yes |
400cc |
17" x 2" |
1/8" |
8127 |
||
A |
Yes |
400cc |
17" x 2" |
1/4" |
8130 |
||
Cartridge Format* |
B |
Cartridge Moisture Trap |
Yes |
- |
13" x 1.5" |
- |
81005 |
In-Line Format |
C |
In-Line Moisture Trap |
Yes |
120cc |
14.5" x 1.5" |
1/8" |
8121 |
C |
Yes |
120cc |
14.5" x 1.5" |
1/4" |
8125 |
||
C |
Yes |
400cc |
17" x 2" |
1/8" |
8123 |
||
C |
Yes |
400cc |
17" x 2" |
1/4" |
8128 |
||
D |
Glass Moisture Trap |
Yes |
100cc |
13" x 1.5" |
1/8" |
7214 |
|
D |
Yes |
100cc |
13" x 1.5" |
1/4" |
7216 |
||
E |
Hight Pressure Gas Drier |
No |
200cc |
10" x 1.5" |
1/4" |
8113 |
|
F |
BIG Moisture Trap |
No |
750cc |
17" x 2.4" |
1/8" |
7207 |
|
F |
No |
750cc |
17" x 2.4" |
1/4" |
7209 |
||
F |
No |
750cc |
17" x 2.4" |
1/2" |
7211 |
||
G |
ALL-Pure™ Moisture Trap |
No |
- |
21" x 1.5" |
1/8" |
7034 |
|
G |
No |
- |
21" x 1.5" |
1/4" |
7036 |
||
H |
Traditional Hydro-Purge® |
Yes |
120cc |
10.5" x 1.5" |
1/8" |
14505 |
|
H |
Yes |
120cc |
10.5" x 1.5" |
1/4" |
14503 |
||
I |
Hydro-Purge II® |
Yes |
120cc |
9" x 1.5" |
1/8" |
14626 |
|
I |
Yes |
120cc |
9" x 1.5" |
1/4" |
14625 |
||
I |
Yes |
200cc |
12" x 1.5" |
1/8" |
14628 |
||
I |
Yes |
200cc |
12" x 1.5" |
1/4" |
14627 |
||
J |
SS Hydro-Purge® |
No |
- |
13" x 1.2" |
1/8" |
14517 |
|
J |
No |
- |
13" x 1.2" |
1/4" |
14515 |
||
K |
Economy Gas Purifiers |
Yes |
200cc |
6" x 2" |
1/8" Brass |
8151 |
|
K |
Yes |
200cc |
6" x 2" |
1/4" Brass |
8153 |
||
K |
Yes |
200cc |
6" x 2" |
1/8" SS |
8155 |
||
K |
Yes |
200cc |
6" x 2" |
1/4" SS |
8157 |
||
L |
Sodium Sulfate Trap |
Yes |
200cc |
6" x 2" |
1/4" |
81533 |
* Requires cartridge Baseplate unit.